Stelflow 120 Indirect Unvented Cylinder TRSMVI-0120LFB

SKU
122627
£562.02
-
+
 
Overview

RM Stelflow Unvented Indirect Cylinder 120 litre. Includes unvented kit.

  • Stainless Steel Tank
  • 25 Year Manufacturer's Guarantee (T&Cs Apply)
  • High Heat Recovery
  • 50mm Insulation for High Energy Efficiency
  • Suitable for Indirect Boiler Systems
  • High Recovery Coil Giving Greater Efficiency
  • Excellent Mains Pressure Flow Rates
  • Includes 22mm Compression Connections

Stelflow 120 Indirect Unvented Cylinder S120I

    A B C D E F G I K
Indirect Product Code HEIGHT DIAMETER COLD WATER INLET PRIMARY COIL FLOW PRIMARY COIL RETURN AQUASTAT POCKET BOTTOM T&P RELIEF VALVE IMMERSION HEATER BOTTOM SECONDRY RETURN
120 TRSMVI-0120LFB 900 545 480 440 200 387 710 686  
150 TRSMVI-0150LFB 1100 545 560 520 200 387 890 670  
180 TRSMVI-0180LFB 1280 545 600 560 200 392 1085 710  
210 TRSMVI-0210LFC 1470 545 640 600 200 467 1265 750 1160
250 TRSMVI-0250LFC 1720 545 640 600 200 467 1520 750 1410
300 TRSMVI-0300LFC 1980 545 640 600 200 467 1785 750 1605
More Information
Delivery Next Business Day
EAN Code 5060162700441
Capacity ERP Type Model Brand
120 L IndirectUnvented INDIRECT STELFLOW
Product Specification
Item category code Stainless Product group code STELFLOW
Warranty terms  (Year) 25Y Max working pressure  (Bar) 3
Heat loss  (kWh_24h) 1.11 Energy usage  (W) 46
Reheat performance  (W) 19.05 Brand STELFLOW
Cylinder style INDIRECT Capacity  (Ltr) 120
Actual capacity  (Ltr) 120 Unit weight empty  (kg) 30
Unit weight full  (kg) 146 Max mains water pressure  (Bar) 10
Operating temp t x0026 p  (C) 95 No heat exchangers 1
No immersions 1 Immersion spec kw 230v 3KW@230V
Coil 1 rating  (kW) 15.63 Coil 1 flow lpm 80c 45
Coil 1 surface area  (m²) .66 Coil 1 fluid content  (Ltr) 3.61
Coil 1 resistance  (Bar) .2 Coil 1 max prim pressure  (Bar) 3.5
Coil 2 flow lpm 80c 0 Tested to standard BS EN 12897:2006
Max fill pressure  (Bar) 3 Expansion vessel pressure  (Bar) 3
Operating pressure t x0026 p  (Bar) 7 Dual stat label 60
Erp profile 0 Energy usage yearly  (kWh) 0
Cylinder material LDX 2101 Thermal insulation DENSE PU FOAM
Outer casing COATED MILD STEEL Coil material 316L STAINLESS STEEL